HomeProductsIntelligent Fire Alarm SystemAddressable Fire Alarm ModuleNon coding detector relay module
  • Non coding detector relay module

Non coding detector relay module

    Payment Type: L/C,T/T,D/P
    Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
    Min. Order: 1 Bag/Bags

Basic Info

Model No.: TX7201

Additional Info

Packaging: Carton

Brand: TNA

Transportation: Ocean,Air

Place of Origin: SHENZHEN

Port: YANTIAN,SHEKOU

Product Description

Addressable Zone Monitor Unit

TX7201 Addressable Zone Monitor unit is an addressable interface module, which will integrate conventional detectors or conventional manual call points to addressable system. When any of the connected devices alarms are active, the unit can send the alarm message to fire alarm controller,which generates alarm signal and displays its address. The unit can match with the conventional optical smoke detector, conventional rate of rise and fixed temperature detector and Conventional Manual Call Point etc. It has the function of checking short or open circuit of the output connection,by the End of Line Resistor (EOLR). The fault massage includes open circuit, short circuit or any removal of the detectors.

The unit manufactured base on the requirement of EN 54 part 18, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs and its plug-in type assembles make installation and maintenance more convenient to the installer. The unit is compatible to the TX7 series Analogue Intelligent Fire Alarm Control Panel, produced by single manufacture T&A, to avoid addressable communication compatibility problem.


Feature and Benefits

  • EN54-18 Compliance
  • Built-in MCU processor and digital addressing
  • Intelligent self-diagnosis of open circuit
  • Enhanced capacity of interference resistance by using multilevel wave filtering process
  • LED status indicator
  • Onsite Adjustable Parameter
  • Loop and external power input
  • Aesthetically pleasing design
  • Parallel connecting up to 16 conventional detector
  • Unit mounting with fix base for simple installation

Technical Specification

  • Listed LPCB Pending
  • Compliance EN54-18:2005/AC2007
  • Input Voltage Loop Power:24VDC [16V to 28V]
External PSU: 20 to 28VDC
  • Current Consumption Loop: Standby 1.3mA, Alarm: 5mA
External PSU: Standby10mA, Alarm: 60mA
  • Control output voltage 24VDC (Only for the use of TX7130, Do not allow the short circuit)
  • End of line Resistance 5.1Kohms/ ¼ W
  • Protocol/Addressing T&A, Value range from 1 to 254
  • Indicator Status Normal: Single blink/Active: Steady/Fault: Double Blink
  • Material / Colour ABS / White Glossy finishing
  • Dimension / LWH 108 mm x 86 mm x38 mm
  • Weight 154g (with Base), 83g (without Base)
  • Operating Temperature -10°C to +50°C
  • Ingress Protection Rating IP30
  • Humidity 0 to 95% Relative Humidity, Non condensing


Addressable Zone Monitor Module






Looking for ideal Non Coding Detector Relay Module BOSCH Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the BOSCH Non Coding Detector Relay Module are quality guaranteed. We are China Origin Factory of Conventional Detector Relay Module Gst. If you have any question, please feel free to contact us.